- 1.
Prepare a plan to investigate how initial hydrochloric acid concentration affects the maximum temperature rise on adding 25.0 cm^3 acid to 25.0 cm^3 of 1.00 mol/dm^3 sodium hydroxide, both initially at 22.0 degrees C. Acid concentrations are 0.20, 0.40, 0.60 and 0.80 mol/dm^3. Formulate a research question, identify one controlled variable with a control method, and explain why the base is in excess throughout. This is planning only.
[3 marks]Worked explanation
- Define the independent variable as acid concentration and the dependent variable as maximum temperature minus initial temperature. Specify the range and volumes so the question is reproducible.
- Neutralisation uses one mole OH- per mole H+. The maximum acid amount, 0.0200 mol, remains below the fixed base amount, 0.0250 mol. Control heat-transfer conditions and initial temperatures to avoid confounding the concentration effect.
Common mistake: Describing acid concentration as the only factor while changing the cup or starting temperature introduces confounding variables.
Marking points
- A measurable question links initial HCl concentration in the given range to maximum temperature rise for the stated fixed volumes and initial temperature.
- One valid control and method, such as the same insulated cup and lid for every trial or equilibration of both reagents to 22.0 degrees C in a water bath.
- The largest acid amount is 0.0250 x 0.80 = 0.0200 mol, below 0.0250 mol NaOH; the 1:1 reaction therefore leaves base in excess at every concentration.
Examiner tip: Describing acid concentration as the only factor while changing the cup or starting temperature introduces confounding variables.
- 2.
Hypothetical acid titration titres are 24.60, 24.70 and 24.65 cm^3. Each titre is the difference of two burette readings, each with absolute uncertainty +/-0.05 cm^3. Calculate the mean titre, the conservative absolute uncertainty of one titre by adding reading uncertainties, and that uncertainty as a percentage of the mean. Do not claim this accounts for all sources of uncertainty.
[3 marks]Worked explanation
- The mean is (24.60 + 24.70 + 24.65)/3 = 24.65 cm^3; the close spread describes repeatability, not proof of accuracy.
- Subtracting two readings requires both reading uncertainties: under the specified conservative rule they sum to 0.10 cm^3. Relative to 24.65 cm^3 this is 0.406%, approximately 0.41%; it is not a statistical confidence interval for the mean.
Common mistake: Dividing 0.10 by three treats a conservative per-titre instrument bound as if it were a statistical uncertainty of the mean.
Marking points
- Mean titre = 24.65 cm^3.
- Conservative absolute uncertainty of one titre = +/-0.10 cm^3.
- Percentage uncertainty = 0.10/24.65 x 100 = approximately 0.41%.
Examiner tip: Dividing 0.10 by three treats a conservative per-titre instrument bound as if it were a statistical uncertainty of the mean.
- 3.
A hypothetical cup-calorimetry trial gives q = +3.60 kJ absorbed by the solution when 0.0800 mol of limiting reagent reacts. Calculate the measured molar reaction enthalpy. Explain the expected direction of bias if heat escapes to the room, and propose one specific improvement. Assume the reaction is exothermic and heat loss is the only bias under discussion.
[3 marks]Worked explanation
- The reaction releases the heat that the solution absorbs, so q(reaction) = -3.60 kJ and the molar value is -45.0 kJ/mol.
- Unrecorded heat escaping the cup reduces the measured solution warming. Improve thermal isolation, while recognising that a lid alone does not quantify or eliminate all heat transfer.
Common mistake: Giving +45.0 kJ/mol uses the solution's heat sign as the exothermic reaction's sign.
Marking points
- Measured reaction enthalpy = -3.60/0.0800 = -45.0 kJ/mol.
- Heat loss makes the measured temperature rise and magnitude of exothermic enthalpy too small, so the result is less negative than the true value.
- A specific heat-loss reduction such as fitting an insulating lid or using additional insulation, linked to reduced transfer to the room.
Examiner tip: Giving +45.0 kJ/mol uses the solution's heat sign as the exothermic reaction's sign.
- 4.
For written investigation preparation, a hypothetical gas-collection method gives 18.0 cm^3 after 60.0 s for a reacting mixture. A matched non-reacting blank gives 3.0 cm^3 from thermal expansion over that interval. Assume this background is additive and identical in both runs. Calculate the blank-corrected volume and mean gas-production rate. Explain how a delay in sealing the reacting apparatus could bias the result even after blank correction, and propose a specific design change.
[4 marks]Syllabus placement evidence: Chemistry subject brief, first assessment 2025, p.2 Reactivity 2.2; p.3 Inquiry process, Exploring and designing / Collecting and processing data / Concluding and evaluating. Uses gas-volume rates to evaluate two measurement mechanisms under stated assumptions. This is SL scientific-investigation preparation, not a completed reaction experiment, a prescribed apparatus mandate or an IA award.
Worked explanation
- The stated additive model permits subtracting the blank before dividing by the shared elapsed time. This rate is a finite-interval mean, not an instantaneous initial rate.
- A blank estimates an unwanted positive signal; loss before collection is a different, negative bias. A sealed initiation design targets the lost-gas mechanism without obstructing gas expansion.
Common mistake: A blank corrects only the background it represents; it cannot correct gas that escaped before measurement.
Marking points
- Corrected volume=18.0-3.0=15.0 cm^3.
- Mean rate=15.0/60.0=0.250 cm^3 s^-1.
- Gas escaping before sealing is missing from the reacting measurement, biasing collected volume/rate low; subtracting a blank cannot recover it.
- Plan to initiate mixing within an already sealed, pressure-safe gas-syringe system, for example using a tipping vessel, with appropriate supervision and a freely moving syringe.
Examiner tip: A blank corrects only the background it represents; it cannot correct gas that escaped before measurement.
- 5.
In a hypothetical written investigation, a thermometer reads 24.0, 24.1 and 24.0 degrees C in a well-mixed reference bath independently established as 25.0 +/-0.1 degrees C. Calculate the mean reading and its range. Evaluate whether the tight cluster establishes accuracy, and propose a check needed before applying one additive correction to reaction measurements spanning 20-50 degrees C.
[4 marks]Syllabus placement evidence: Chemistry subject brief, first assessment 2025, p.3 Skills in the study of chemistry, Tools/Experimental techniques and Inquiry process, Concluding and evaluating. Evaluates thermometer repeatability and calibration in written SL investigation preparation. Supplied reference values are hypothetical; no actual calibration, manipulation or teacher-assessed investigation is claimed.
Worked explanation
- Sum the three readings to 72.1 and divide by three. The range 24.1-24.0 is small relative to the roughly one-degree disagreement with the reference.
- One reference point cannot separate a fixed zero error from an incorrect scale response. Multiple equilibrated reference checks across the measurement interval test whether the same correction is defensible; extra decimals in the mean do not improve instrument resolution.
Common mistake: A small range indicates repeatability, not agreement with a reference or validity of a correction over every temperature.
Marking points
- Mean=24.0333... degrees C, approximately 24.03 degrees C as an intermediate calculation.
- Range=0.1 degrees C, indicating close repeatability in this bath.
- The mean is about 0.97 degrees C below the reference; close repeats do not establish accuracy and suggest a systematic discrepancy under these conditions.
- Compare against independent reference temperatures across 20-50 degrees C after equilibration to determine whether an additive offset, rather than a scale-dependent error, is appropriate.
Examiner tip: A small range indicates repeatability, not agreement with a reference or validity of a correction over every temperature.
- 6.
For written investigation preparation, a hypothetical chromatogram has a solvent front 6.0 cm above its pencil baseline. Two spots from a mixture have centres 3.6 cm and 1.8 cm above that same baseline. Define Rf as spot distance divided by solvent-front distance and calculate both values. Under these conditions, which component has the greater relative attraction to the stationary phase? A reference substance run alongside has Rf=0.60: explain why this does not prove the identity of the first component. State where the initial solvent surface must be relative to the baseline and why.
[5 marks]Syllabus placement evidence: Chemistry guide, first assessment 2025, Structure 2.2.10, printed p.41; Skills in the study of chemistry, pp.27-32. SL chromatography calculations and interpretation are embedded in written investigation preparation. This does not establish practical performance or a completed scientific investigation.
Worked explanation
- Measure both distances from the same starting line, not from the paper edge. Dividing 3.6 and 1.8 by 6.0 gives 0.60 and 0.30, with centimetres cancelling.
- The smaller value describes stronger relative stationary-phase retention under the stated conditions, not a universal polarity ranking independent of the phases. Coincident migration cannot exclude a different substance or unresolved co-migration.
- Starting the solvent below the sample line lets the moving solvent carry the sample up the stationary phase instead of washing it into the reservoir. This is hypothetical interpretation and planning, not evidence of completed chromatography.
Common mistake: Matching one Rf proves neither unique identity nor purity of an unresolved spot.
Marking points
- First spot: Rf=3.6/6.0=0.60; Rf has no units.
- Second spot: Rf=1.8/6.0=0.30.
- The second component travels less relative to the solvent front, indicating greater relative retention by the stationary phase in this system.
- A matching Rf is consistent with the reference but is not unique identification: different substances may have the same Rf. Further evidence, such as a second suitable solvent system or an independent technique, is needed.
- The initial solvent surface must be below the baseline so the applied sample does not dissolve directly into the solvent reservoir.
Examiner tip: Matching one Rf proves neither unique identity nor purity of an unresolved spot.
- 7.
In written investigation preparation, a hypothetical hydrogen discharge spectrum shows separated visible lines near 410, 434, 486 and 656 nm, with dark regions between them. These lines arise from transitions from n=6,5,4 and 3 respectively to n=2. Explain why this is a line rather than a continuous spectrum and what it implies about atomic energy levels. Identify the initial level for the 656 nm line and explain whether an electron gains or loses energy when it produces that line. Which of the four photons has greatest energy, and why? Use the qualitative inverse relationship between photon energy and wavelength; no numerical photon-energy calculation is required.
[4 marks] · no calculatorSyllabus placement evidence: IB Chemistry guide, first assessment 2025, Structure 1.3.1-1.3.2, printed pp.34-35; Inquiry 2 link to emission-spectrum observations. Targets prescribed SL qualitative spectrum interpretation through hypothetical investigation data. Numerical ionisation energy is reserved for the separate HL task; no discharge-tube operation or practical completion is claimed.
Worked explanation
- A continuous distribution would fill the intervening wavelengths. Hydrogen instead emits photons corresponding to selected differences between allowed atomic levels.
- Read the supplied assignments: 656 nm comes from level 3, not level 6. Emission transfers energy out of the atom as the electron drops to n=2.
- For the same final level, the higher starting levels give larger energy drops. Thus the shortest supplied wavelength, 410 nm, represents the largest photon energy. This does not require SL recall of a named spectral series.
Common mistake: Excitation to a higher level absorbs energy; the observed emission occurs during the subsequent downward transition.
Marking points
- Only particular wavelengths are emitted, separated by dark intervals, rather than an uninterrupted range: this is a line spectrum.
- The lines are evidence for discrete electron energy levels: only specific differences between allowed levels produce photons.
- The 656 nm line is n=3 to n=2; the electron loses energy and emits a photon on falling to the lower level.
- The 410 nm photon has greatest energy because it has the shortest wavelength and therefore highest frequency among these lines.
Examiner tip: Excitation to a higher level absorbs energy; the observed emission occurs during the subsequent downward transition.
- 8.
For written investigation preparation, 0.120 g of an unknown gas occupies 100.0 cm^3 at 100.0 kPa and 300 K. Assume a pure dry ideal gas and that the stated pressure is its pressure. Use PV=nRT with R=8.314 Pa m^3 mol^-1 K^-1. Convert pressure and volume to SI units, calculate the amount and molar mass of the gas, and predict its volume if pressure doubles at the same temperature with the amount fixed. Explain why using a lower temperature and higher pressure would generally make the ideal-gas assumption less reliable.
[5 marks]Syllabus placement evidence: IB Chemistry guide, first assessment 2025, Structure 1.5.1-1.5.4, printed pp.37-38; Tool 1/Inquiry 2 gas molar-mass link. Adds the prescribed SI ideal-gas calculation and experimental molar-mass inference, not another fixed molar-volume substitution. Written SL preparation with all constants supplied, not completed gas measurement.
Worked explanation
- Using pascals and cubic metres makes PV=10.00 Pa m^3=10.00 J, compatible with the supplied R. Retain the unrounded amount 0.0040093 mol for the next calculation.
- Dividing sample mass by amount gives 29.9304 g mol^-1. The gas formula cannot be selected uniquely just by rounding this molar mass.
- The inverse volume-pressure prediction holds only while temperature, amount and ideal behaviour remain fixed. The model's negligible-volume and negligible-attraction assumptions become poorer under compression and cooling.
Common mistake: Mixing kPa or cm^3 with the supplied SI gas constant produces factors of 1000 or a million.
Marking points
- P=1.000 x 10^5 Pa and V=1.000 x 10^-4 m^3; both conversions required.
- n=PV/(RT)=10.00/(8.314 x 300)=0.00401 mol approximately.
- M=0.120/n=29.9 g mol^-1 approximately; this alone does not uniquely identify the gas.
- At fixed n and T, PV is constant, so doubling pressure halves volume to 5.00 x 10^-5 m^3 (50.0 cm^3).
- At lower temperature attractions are less negligible relative to kinetic energy, and at higher pressure finite particle volume and interactions become more significant; real gases therefore generally depart further from this model.
Examiner tip: Mixing kPa or cm^3 with the supplied SI gas constant produces factors of 1000 or a million.
- 9.
In a hypothetical polymer-preparation record, 0.300 mol of propene, CH2=CHCH3, is the only monomer feed. Its molar mass is 42.0 g mol^-1. Model addition polymerisation without small-molecule by-products and neglect initiator/end-group mass. Give a repeat unit for the polymer, showing its two backbone connections, and explain how the C=C bond and connections between monomers change as chains form. Calculate the theoretical polymer mass and the percentage isolated yield if 12.0 g of pure dry polymer is recovered. Explain why this reaction can have 100% atom economy even though its isolated yield is below 100%.
[5 marks]Syllabus placement evidence: IB Chemistry guide, first assessment 2025, Structure 2.4.4-2.4.5, printed p.43; Reactivity 2.1.4-2.1.5, printed p.52. Adds prescribed SL addition-polymer representation and a quantitative atom-economy/yield distinction to a written preparation record. No actual synthesis, polymer performance or full materials coverage is asserted.
Worked explanation
- Follow the two alkene carbons into the backbone and leave CH3 attached to its original carbon. Writing [-CH2-CH2-] would discard that substituent and is not the polymer of propene.
- No stoichiometric small molecule is removed, so the limiting monomer mass is the maximum polymer mass in this model. Compare recovered pure dry mass with 12.6 g, not with the number of monomer moles.
- Atom economy describes the equation's potential incorporation of atoms. Yield describes this preparation's outcome; 95.2% recovery is not evidence for a 4.8% stoichiometric by-product.
Common mistake: Keeping the C=C inside a repeat unit while adding backbone links can give carbon more than four bonds.
Marking points
- Repeat unit [-CH2-CH(CH3)-] with bonds continuing through both brackets; reversed equivalent orientation accepted.
- The C=C becomes a single C-C bond and new C-C bonds link neighbouring monomers into the chain. This connectivity explanation earns the mark without pi/sigma terminology; accurate optional use of those terms is also accepted.
- Theoretical mass=0.300 x 42.0=12.6 g under the stated model.
- Isolated yield=12.0/12.6 x 100=95.2% approximately.
- All monomer atoms can enter the intended addition polymer, giving 100% theoretical atom economy; incomplete conversion or recovery losses can still reduce the isolated yield.
Examiner tip: Keeping the C=C inside a repeat unit while adding backbone links can give carbon more than four bonds.