Original English practice with worked guidance. Selected topics only. This is not a complete syllabus, official past-paper collection or predicted exam score. Check your own exam-board specification: these concepts are not certified against a particular board or exam year. Where a question shows a Cambridge 2027 reference, that is a conceptual placement only; no other exam board (such as Edexcel, AQA or OCR) is mapped, so do not assume this covers your board. Content here is written and checked with AI assistance; it has not been approved by an independent teacher or endorsed by any exam board.
125 original questions across 15 selected topic areas. No account or payment required to practise.
Cambridge International AS & A Level Physics (9702), examination year 2027: Conceptual alignment to official sources, not exam-board certification. Syllabus mapping and remaining coverage.
8 questions in this topic
Original questions with indicative worked guidance. Selected topics only.
All topics
Original application practice with worked explanations and indicative self-marking points. Not an official exam paper or a board-specific assessment.
Parallel plates have a potential difference of 600 V and separation 0.020 m. Assume a uniform field. Calculate its magnitude and the magnitude of the force on a charge of +2.0 microcoulombs.
Cambridge 2027: Direct conceptual match
Parallel-plate E=V/d and force qE directly address uniform fields.
Conceptual placement only, not official Cambridge endorsement or complete syllabus coverage.
Show indicative guidance
Worked guidance
The field is the potential difference per metre, not voltage multiplied by distance.
Convert 2.0 microcoulombs to 2.0 x 10−6 C before using F = qE.
A positive charge experiences force along the electric field, from the positive plate towards the negative plate.
Self-marking points
Tick what your working earned. The count is your own self-assessment.
Self-assessed: not counted yet. This question is worth 3 marks.
Examiner tip
Convert both the plate separation and the charge to SI units first.
Question 2A detector reads 820 counts per minute initially and 120 counts per minute 6.0 hours later. Background is constant at 20 counts per minute. Assuming exponential decay, find the sample's half-life.4 indicative marks
A detector reads 820 counts per minute initially and 120 counts per minute 6.0 hours later. Background is constant at 20 counts per minute. Assuming exponential decay, find the sample's half-life.
Cambridge 2027: Direct conceptual match
Background-corrected count-rate ratio gives three half-lives; quantitative decay is explicit A-level content.
Conceptual placement only, not official Cambridge endorsement or complete syllabus coverage.
Show indicative guidance
Worked guidance
Subtract the same background from both readings; the background is not part of the decaying sample.
Compare corrected rates: 800 -> 400 -> 200 -> 100. This is three successive halvings.
Divide the total elapsed time by three. Count rates are proportional to activity under unchanged measurement conditions.
Self-marking points
Tick what your working earned. The count is your own self-assessment.
Self-assessed: not counted yet. This question is worth 4 marks.
Examiner tip
Taking 120/820 without removing background gives an incorrect decay ratio.
Question 3A metal has work function 2.0 eV. Light of wavelength 400 nm falls on it. Use h = 6.63 x 10−34 J s, c = 3.00 x 108 m s−1 and 1 eV = 1.60 x 10−19 J. Find maximum photoelectron kinetic energy in eV and stopping potential. Explain whether doubling intensity changes stopping potential.4 indicative marks
A metal has work function 2.0 eV. Light of wavelength 400 nm falls on it. Use h = 6.63 x 10−34 J s, c = 3.00 x 108 m s−1 and 1 eV = 1.60 x 10−19 J. Find maximum photoelectron kinetic energy in eV and stopping potential. Explain whether doubling intensity changes stopping potential.
Cambridge 2027: Partial conceptual match
Photon/work-function and intensity reasoning are explicit; stopping potential is an additional application not explicitly named in this subsection.
Conceptual placement only, not official Cambridge endorsement or complete syllabus coverage.
Show indicative guidance
Worked guidance
Convert wavelength to 4.00 x 10−7 m. With the supplied constants, hc/lambda = 4.9725 x 10−19 J, or approximately 3.1078 eV.
In the single-photon photoelectric model an emitted electron absorbs one photon; this does not mean every incident photon ejects an electron. Kmax = hc/lambda - work function, approximately 1.1 eV at the stated precision.
The stopping-potential magnitude obeys e*V_stop = Kmax, giving approximately 1.1 V. At fixed frequency, intensity changes the incident photon rate, not photon energy.
Self-marking points
Tick what your working earned. The count is your own self-assessment.
Self-assessed: not counted yet. This question is worth 4 marks.
Examiner tip
Greater intensity does not mean greater photon energy. Photon energy depends on frequency.
Question 4Two fixed positive point charges are placed on the x-axis: +Q at x=0 and +4Q at x=0.300 m, where Q>0. With no other electric fields present, find the finite point on the x-axis where the resultant electric field is zero. Explain the relative field directions between and outside the charges; exclude the charge positions themselves.5 indicative marks
Two fixed positive point charges are placed on the x-axis: +Q at x=0 and +4Q at x=0.300 m, where Q>0. With no other electric fields present, find the finite point on the x-axis where the resultant electric field is zero. Explain the relative field directions between and outside the charges; exclude the charge positions themselves.
Cambridge 2027: Direct conceptual match
A-level9702 field as force per unit charge and Coulomb inverse-square force, with explicit vector superposition of two stated point sources.
Conceptual placement only, not official Cambridge endorsement or complete syllabus coverage.
Show indicative guidance
Worked guidance
A positive source produces field pointing away from it. Between the charges, the left source contributes rightward and the right source contributes leftward; outside the pair both contributions point toward the same axial direction.
For 0<x<0.300, divide the Coulomb forces on a positive test charge by that test charge. The common Coulomb constant and Q cancel, leaving 1/x2=4/(0.300-x)^2.
Both distances are positive, so taking the positive square root gives 0.300-x=2x. Solve to getx=0.100 m, leaving 0.200 m to the larger source.
At those distances the fields are proportional to Q/0.100^2 and 4Q/0.200^2, which agree. The test point is nearer the smaller charge; equal electric potential was not the required condition.
Self-marking points
Tick what your working earned. The count is your own self-assessment.
Self-assessed: not counted yet. This question is worth 5 marks.
Examiner tip
Fields add as vectors. Equal positive charges need not be assumed, and equal field magnitudes do not mean equal distances for unequal source charges.
Question 5A model nucleus containing four nucleons has a mass defect of 0.0300 u relative to the same separated nucleons. Use 1 u=1.66 x 10^-27 kg, c=3.00 x 10^8 m s^-1 and 1 MeV=1.60 x 10^-13 J. Calculate its binding energy in joules and MeV, and binding energy per nucleon in MeV, all to 3 significant figures. Explain the physical meaning of the positive binding energy; this is supplied model data, not a claim about a named isotope.5 indicative marks
A model nucleus containing four nucleons has a mass defect of 0.0300 u relative to the same separated nucleons. Use 1 u=1.66 x 10^-27 kg, c=3.00 x 10^8 m s^-1 and 1 MeV=1.60 x 10^-13 J. Calculate its binding energy in joules and MeV, and binding energy per nucleon in MeV, all to 3 significant figures. Explain the physical meaning of the positive binding energy; this is supplied model data, not a claim about a named isotope.
Cambridge 2027: Direct conceptual match
A-level9702 section23.1 mass-energy equivalence, mass defect and binding energy per nucleon; no isotope-specific measured masses or reaction products invented.
Conceptual placement only, not official Cambridge endorsement or complete syllabus coverage.
Show indicative guidance
Worked guidance
Convert the mass defect before using E=delta m c2: 0.0300 x 1.66 x 10−27=4.98 x 10−29 kg. The defect is the separated-nucleon mass minus the bound nuclear mass.
Using the supplied speed of light gives E=(4.98 x 10−29)(3.00 x 108)^2=4.482 x 10−12 J, which rounds to 4.48 x 10−12 J.
Divide the unrounded energy by 1.60 x 10−13 J per MeV: 28.0125 MeV, or 28.0 MeV to 3 significant figures. Divide that unrounded total by four for 7.003125 MeV per nucleon, rounding to 7.00.
The bound system has lower rest energy than its separated constituents. Breaking it apart therefore requires input of the positive binding energy; it does not release that amount by simple separation.
Self-marking points
Tick what your working earned. The count is your own self-assessment.
Self-assessed: not counted yet. This question is worth 5 marks.
Examiner tip
Divide the total energy by the number of nucleons only once. Keep guard digits through unit conversion, then round the final quantities.
Question 6Fictional expected detector rates at t=0,4,8 hours are 140,80,50 counts per minute. Treat these as exact means for a single exponentially decaying source plus unknown constant background B. (a) Derive an equation for B and determine it. (b) Find the half-life. (c) Explain why three actual short counts would not justify reporting this half-life as exact.6 indicative marks
Fictional expected detector rates at t=0,4,8 hours are 140,80,50 counts per minute. Treat these as exact means for a single exponentially decaying source plus unknown constant background B. (a) Derive an equation for B and determine it. (b) Find the half-life. (c) Explain why three actual short counts would not justify reporting this half-life as exact.
Cambridge 2027: Partial conceptual match
Adds simultaneous inference of unknown constant background and half-life from equally spaced mean rates. Selected aspects only; the referenced outcome rows are not certified complete.
Conceptual placement only, not official Cambridge endorsement or complete syllabus coverage.
Show indicative guidance
Worked guidance
Write net expected rate as A0*rk at equally spaced times. Eliminating r gives 6400-160B+B2=7000-190B+B2, so 30B=600.
Subtracting 20 yields a common ratio 1/2. The exact arithmetic applies to the fictional means, not to noisy observations from an actual detector.
Reconstruct the supplied rates: 20+120=140, 20+120/2=80, and 20+120/4=50 counts per minute. This validates the single-component model for the supplied means only.
Self-marking points
Tick what your working earned. The count is your own self-assessment.
Self-assessed: not counted yet. This question is worth 6 marks.
Examiner tip
A background must be subtracted before comparing decay ratios. Indicative self-marking only
Question 7A fictional detector records 900 counts in 5 minutes initially and 300 counts in 5 minutes after 8 hours. A separate 10-minute background record contains 200 counts. Treat these as noiseless model counts for a single decaying isotope and constant background. Assume negligible decay within each counting window and approximate its mean rate by the instantaneous rate at the stated time. (a) Find corrected rates and half-life. (b) Predict total expected counts in a 2-minute window at 12 hours. (c) Explain why this exact-count model is not a realistic uncertainty statement.5 indicative marks
Calculate and explain5 indicative marksCalculator allowed
A fictional detector records 900 counts in 5 minutes initially and 300 counts in 5 minutes after 8 hours. A separate 10-minute background record contains 200 counts. Treat these as noiseless model counts for a single decaying isotope and constant background. Assume negligible decay within each counting window and approximate its mean rate by the instantaneous rate at the stated time. (a) Find corrected rates and half-life. (b) Predict total expected counts in a 2-minute window at 12 hours. (c) Explain why this exact-count model is not a realistic uncertainty statement.
Cambridge 2027: Partial conceptual match
Original multipart practice in Background-corrected half-life. Selected written evidence only; not complete outcome coverage, practical certification.
Conceptual placement only, not official Cambridge endorsement or complete syllabus coverage.
Show indicative guidance
Worked guidance
First normalise all counts by their different collection times: 900/5=180, 300/5=60 and 200/10=20 per minute. Subtract rates, not raw totals.
The net rate falls from 160 to 40 through two half-lives. Three half-lives have elapsed at 12 hours, leaving 160/8=20 per minute from the source.
Add the background back before multiplying by the requested window: (20+20)*2=80. Actual short records need uncertainty treatment; the stipulated window-rate approximation supports only this model estimate.
Self-marking points
Tick what your working earned. The count is your own self-assessment.
Self-assessed: not counted yet. This question is worth 5 marks.
Examiner tip
State assumptions, units and the limits of the evidence. Indicative self-marking only
Question 8A metal's stopping potential is 0.40 V at frequency 6.0e14 Hz and 1.20 V at 8.0e14 Hz. Assume the linear photoelectric model and use e=1.60e-19 C. (a) Infer h from the slope and the threshold frequency. (b) Find the model work function in joules. (c) Predict whether 4.0e14 Hz light ejects electrons when its intensity is increased.5 indicative marks
Calculate, analyse and evaluate5 indicative marksCalculator allowed
A metal's stopping potential is 0.40 V at frequency 6.0e14 Hz and 1.20 V at 8.0e14 Hz. Assume the linear photoelectric model and use e=1.60e-19 C. (a) Infer h from the slope and the threshold frequency. (b) Find the model work function in joules. (c) Predict whether 4.0e14 Hz light ejects electrons when its intensity is increased.
Cambridge 2027: Partial conceptual match
Original multipart practice in Photoelectric energy and stopping potential. Selected written evidence only; not complete outcome coverage, practical certification.
Conceptual placement only, not official Cambridge endorsement or complete syllabus coverage.
Show indicative guidance
Worked guidance
Use eVs=hf-phi, so the voltage-frequency slope is h/e. The 0.80 V rise over 2.0e14 Hz gives 4.0e-15 V s.
Extrapolate to zero stopping voltage: f0=6.0e14-0.40/(4.0e-15)=5.0e14 Hz. Multiplying the inferred h by this intercept gives phi=3.2e-19 J.
The data are stipulated model measurements, so the inferred h need not equal a more precise tabulated constant. Below threshold each photon lacks sufficient energy; higher photon arrival rate does not change individual photon energy under this model.
Self-marking points
Tick what your working earned. The count is your own self-assessment.
Self-assessed: not counted yet. This question is worth 5 marks.
Examiner tip
State assumptions, units and the limits of the evidence. Indicative self-marking only